MAS AUTOMATION

 
 
 

SUPPLIERS

 
 
 
 
Home > IBHSoftec
Hardware

 

Hardware

IBHsoftec offers hardware for use with Siemens PLC controls .
The S5 series as well as the S7-200®, S7-300® and S7-400® series are supported.

S7-PCI315



The S7-PCI315  executes a program in the same manner as a Siemens PLC. The advantage of executing a PLC program this way is, that the PLC status can be displayed in real time. Since the S7-PCI315 behaves like a original SIMATIC® PLC, the programming tools S7 for Windows® and STEP®7 can be used. Even for project engineering and diagnostics of the PROFIBUS DP, S7 for Windows® or the original STEP®7 tool can be used. The program of a S7-PLC or a Siemens Win AC® SoftPLC including PROFIBUS DP configuration can be transferred to the S7-PCI315.

  • PU functions with STEP®7 or S7 for Windows® via PROFIBUS-DP, USB, Ethernet or directly
  • Operator panels (OPs) and PU devices can be connected in the usual way to PROFIBUS-DP
  • HMI applications can connect via PROFIBUS-DP, USB, Ethernet or directly
  • HMI applications can connect via the optional IBH OPC Server
  • Proven a thousand times, any PROFIBUS-DP module can be used.

Read more...

S7-CX315



  • PU functions with STEP®7 or S7 for Windows® over Ethernet with the ISO on TCP (RFC1006) or the IBHLink protocol
  • Online connections via PROFIBUS-DP are possible with the Beckhoff PROFIBUS Master EL6731.
    Operator panels (OPs) and PU devices can be connected in the usual way to PROFIBUS-DP.
  • HMI applications can connect via ISO on TCP (RFC1006), the IBHLink protocol or via the optional IBH OPC server for the visualization PC.
  • Diagnostics and HMI via Intranet/Internet with the integrated web server.
  • PLC to PLC communication via the integrated Ethernet CP.
  • Based on the reliable and flexible Beckhoff hardware.
  • In conjunction with the Beckhoff TwinSAFE modules, safety functions (f.i. emergency stop) can be realized very easy and cost-efficient with the S7-CX317, S7-CX317S and S7-CX416 PLC.
  • Using the EtherCAT technology, it is possible to integrate other fieldbus segments, as for instance PROFIBUS DP, CANOpen, AS-i, DeviceNet, ControlNet, Modbus, Fipio, CC-Link and SERCOS interface at any place of the EtherCAT network.
  • For the operation in building automation, the bus systems LON, EIB/KNX, MP, as well as DALI are available.
  • Special functions for the peripheral devices (ADS functions) can be called via integrated function blocks.

Read more...


S7-CX317



  • PU functions with Step®7 or S7 for Windows® over Ethernet with the ISO on TCP (RFC1006) or the IBHLink protocol
  • Online connections via PROFIBUS-DP are possible with the Beckhoff PROFIBUS Master EL6731.
    Operator panels (OPs) and PU devices can be connected in the usual way to PROFIBUS-DP.
  • HMI applications can connect via ISO on TCP (RFC1006), the IBHLink protocol or via the optional IBH OPC Server for the visualization PC.
  • Diagnostics and HMI via Intranet/Internet with the integrated web server.
  • PLC to PLC communication via the integrated Ethernet CP.
  • Based on the reliable and flexible Beckhoff hardware.
  • In conjunction with the Beckhoff TwinSAFE modules, safety functions (f.i. emergency stop) can be realized very easy and cost-efficient with the S7-CX315, S7-CX317 and S7-CX416 PLC.
  • Using the EtherCAT technology, it is possible to integrate other fieldbus segments, as for instance PROFIBUS DP, CANOpen, AS-i, DeviceNet, ControlNet, Modbus, Fipio, CC-Link, EtherNet/IP, and SERCOS interface at any place of the EtherCAT network.
  • For the operation in building automation, the bus systems LON, EIB/KNX, MP, as well as DALI are available.
  • Special functions for the peripheral devices (ADS functions) can be called via integrated function blocks.

Read more...

S7-CX416


  • PU functions with Step®7 or S7 for Windows® over Ethernet with the ISO on TCP (RFC1006) or the IBHLink protocol
  • Online connections via PROFIBUS-DP are possible with the Beckhoff PROFIBUS Master EL6731.
    Operator panels (OPs) and PU devices can be connected in the usual way to PROFIBUS-DP.
  • HMI applications can connect via ISO on TCP (RFC1006), the IBHLink protocol or via the optional IBH OPC Server for the visualization PC.
  • Diagnostics and HMI via Intranet/Internet with the integrated web server.
  • PLC to PLC communication via the integrated Ethernet CP.
  • Based on the reliable and flexible Beckhoff hardware.
  • In conjunction with the Beckhoff TwinSAFE modules, safety functions (f.i. emergency stop) can be realized very easy and cost-efficient with the S7-CX315, S7-CX317 and S7-CX416 PLC.
  • Using the EtherCAT technology, it is possible to integrate other fieldbus segments, as for instance PROFIBUS DP, CANOpen, AS-i, DeviceNet, ControlNet, Modbus, Fipio, CC-Link, EtherNet/IP, and SERCOS interface at any place of the EtherCAT network.
  • For the operation in building automation, the bus systems LON, EIB/KNX, MP, as well as DALI are available.
  • Special functions for the peripheral devices (ADS functions) can be called via integrated function blocks.
  • The S7-CX416 PLC is available with DVI/USB interface.

Read more...

S5-CX945


Replacement for existing S5 PLC
The high performance S5-CX945 is a S5-115U compatible PLC based on Beckhoff hardware.

Since the new S5-CX series behaves like a original SIMATIC® PLC, the programming tools S5 for Windows® and STEP®5 can be used. Online connections can be established via Ethernet and the integrated serial ports. The S5-CX executes a program in the same manner as a hardware PLC. The program of a S5-PLC can be transferred to the S5-CX series.

As hardware platform for the S5-CX, the modular DIN rail PCs of the CX series of the Beckhoff automation GmbH is used. The fieldbus used to control the central and the distributed I/O primarily is EtherCAT (Real-Time Ethernet).


  • Compatible to CPU 945 from the115U-series.
  • PU functions with STEP®5 or S5 for Windows® over Ethernet and the integrated serial ports.
  • HMI applications can connect serial (RS232) via AS511-protocol, via IBHLink S5 IBHLink S5 Variables protocol, INAT TCP/IP PG protocol, Send Receive over TCP/IP, UDP and RFC1006, Fetch/Write passive over TCP/IP and RFC1006 ISO on TCP (RFC1006), or via the optional IBH OPC server for the visualization PC. PG protocol,
  • Modbus TCP Server.
  • S7 Operator panels can be connected in the usual way via PROFIBUS or Ethernet
  • Diagnostics and HMI via Intranet/Internet with the integrated web server.
  • PLC to PLC communication via the integrated Ethernet CP.
  • Based on the reliable and flexible Beckhoff hardware.
  • In conjunction with the Beckhoff TwinSAFE modules, safety functions (f.i. emergency stop) can be realized very easy and cost-efficient with the S5-CX945 PLC.
  • Using the EtherCAT technology, it is possible to integrate other fieldbus segments, as for instance PROFIBUS DP, CANOpen, AS-i, DeviceNet, ControlNet, Modbus, Fipio, CC-Link, EtherNet/IP, and SERCOS interface at any place of the EtherCAT network.
  • For the operation in building automation, the bus systems LON, EIB/KNX, MP, as well as DALI are available.
  • Special functions for the peripheral devices (ADS functions) can be called via integrated function blocks.

Read more...

Accessories

AC/DC Adapter 24 V


AC/DC Adaptor 24 V for IBH Link S5, IBH Link S7, IBH Link S7 Plus If no 24V is supplied, the AC/DC Adaptor delivers the 24 V.

 

RJ45 Crossover Adapter



For direct connection of the IBH Link S7 to the network card of the PC.

For connection of the IBH Link S7 Crossover to a switch or hub.

 

RJ45 female to female connector



For extending the RJ45 line of the IBH Link S5, the IBH Link S7,

the IBH Link S7 Crossover or the IBH Link S7 Plus


Dial In/Out Ethernet-Router


The IBH ZR-200 is a compact Ethernet-Router for industrial applications. Because of its integrated modem and its compact dimensions, it can be easily integrated into new as well existing systems.

It is available in two versions:
IBH ZR-200 A - Industrial Ethernet-Router with integrated analog Modem
IBH ZR-200 I   - Industrial Ethernet-Router with integrated ISDN Modem

The Dial-IN/OUT Router IBH ZR-200 can be applied wherever an Ethernet system is
to be remotely managed via analog or ISDN dial-up lines.
The IBH ZR-200 enables safe dialling-in via modem to a remote network by way of a
standard PPP connection. The advantage of a router is in the fact that all
participants of the remote network can be accessed.
Additional features are Dial on Demand, Callback and ISP-Dialing with VPN functionality.
  • Integrated Analog/ISDN Modem
  • 24V DC Power supply
  • Space saving solution
  • Configuration via integrated Web surface
  • 10 status LEDs 
  • RJ45 ethernet connector
  • ISDN-64kBit/s analog 33.6kBit/s
  • Remote configurable
  • Secure PPP-connections
  • Dial In/Out (new) 
  • Call Back (new) 
  • Dial on Demand (new) 
  • ISP Dialling
  • VPN-connections

S5/S7 Eprommer/Erasures

USB S5/S7 Prommer (Siemens)


The USB S5/S7 Prommer is used to program S5 Eproms, S5 EEproms, S5/S7 Flash Eproms and S7 MicroMemoryCards.
The USB S5/S7 Prommer is connected via the USB port of the PC.
All Eprom functions such as erasing, displaying, reading, transferring, comparing, and erase check are available.
The USB S5/S7 Prommer works together with S5/S7 for Windows® , STEP®5 and STEP®7


FlashPrommer


The FlashPROMMER is used to program the new Memory Cards (Flash PROMMS) for the S5 and the S7-300® and S7-400® PLC series.
The FlashPROMMER is handled in exactly the same way as the Eprommer.
The FlashPROMMER is also connected via the parallel printer port of the PC.
All Eproms options such as erasing, displaying, reading, transferring, comparing, and erase check are available.


EPROM-Eraser LG07


The robust design of this EPROM-Eraser LG07 will withstand even the hardest use. The EPROM-Eraser LG07 has an integrated timer (max. 60 min.) and an indicator to control the erasing procedure. The high power ultraviolet ray lamp has a long life. The ultraviolet ray lamp is turned off if the drawer is opened accidentally. The drawer has roller bearings for easy sliding. Drawer size: 60x90x21mm. The drawer has space for one (1) S5 Eprom Module or up to seven DIP 28 Eprom’s. A 230V / 50/60 Hz 12VA power supply is integrated.


EPROM-Eraser UVL3


Designed for portability the EPROM-Eraser UVL3 offers an easy and safe way to erase Eprom Modules and Eprom chips. The small size and its low weight are the special features of the EPROM-Eraser UVL3. The bottom of the eraser is open. To erase modules the eraser is placed over the Eprom. An adjustable timer to set the erasure time is integrated. The EPROM-Eraser UVL3 can be operated with the 24V from a PLC power supply. Optionally an external 230V / 24V power supply is available.




 

                                       © Middle-East Automation System Trading 2008 (MAS), All rights reserved     Code & Design By MH.com.eg